centro storico, Catania, visione dall'alto dalla terrazza della badia di S.Agata, vulcano Etna

Italy · 10 kWp reference system

Catania solar forecast and PV yield

Photo: Dariolp83,CC BY-SA 4.0. Cropped, resized and converted to WebP by GridPassport.

Forecast target: . Any “tomorrow” label on this page refers to this dated target.

Tomorrow's forecast
50.7 kWh
10 kWp reference system
Typical annual output
15,638 kWh
10 kWp reference system
Typical specific yield
1,564 kWh/kWp
Per year

Tuesday, September 1, 2026

About 50.7 kWh tomorrow

For a standard 10 kWp south-facing system in Catania, GridPassport estimates 50.7 kWh on Tuesday, September 1, 2026, with a likely range of 44.0-53.7 kWh. The strongest production window is expected at 12:00-16:00 local time.

Updated Aug 31, 2026, 01:01 AM GMT+2 · fresh snapshot
Likely range
44.0-53.7 kWh
Strongest window
12:00-16:00
Confidence
high
Forecast my solar output

How to read and use the data

Catania solar forecast: daily weather versus long-term PV yield

The daily and annual figures answer different questions. Use the dated forecast to plan tomorrow, and the PVGIS specific yield to compare locations or estimate a typical year.

Dated, weather-based

Tomorrow's forecast

Tomorrow's value is a weather-based estimate for Tuesday, September 1, 2026: 50.7 kWh from the 10 kWp reference system, with a likely range of 44.0 kWh–53.7 kWh. It changes with the next weather forecast.

Multi-year climate baseline

PVGIS specific yield

Catania's PVGIS specific yield is about 1,564 kWh/kWp per year. It is a multi-year climate benchmark, not a prediction for tomorrow or for this calendar year. In the PVGIS profile, July is typically the strongest month and December the weakest.

3, 5 and 10 kWp reference systems

Scale the same assumptions to your system size

SystemTomorrow estimate (likely range)PVGIS typical year
3 kWpTomorrow estimate (likely range)15.2 kWh13.2 kWh–16.1 kWhPVGIS typical year4,691 kWh/year
5 kWpTomorrow estimate (likely range)25.4 kWh22.0 kWh–26.9 kWhPVGIS typical year7,819 kWh/year
10 kWpTomorrow estimate (likely range)50.7 kWh44.0 kWh–53.7 kWhPVGIS typical year15,638 kWh/year

Linear reference scaling only: south-facing, 35° tilt and 14% system losses. It does not resize inverter clipping, shade or local roof constraints.

From forecast to a household plan

Battery, EV, heat pump and flexible loads

Treat the forecast as a gross solar-energy budget before household base load and conversion losses. The numbers support scheduling; they do not guarantee surplus.

Battery

Keep room for the solar window

Use 12:00-16:00 as the first candidate charging window. Battery state of charge, reserve settings and inverter limits still decide how much can be stored.

Heat pump

Shift only flexible thermal demand

If comfort controls allow it, place discretionary hot-water heating or pre-heating inside 12:00-16:00. Never override frost protection, hygiene cycles or manufacturer limits.

Large loads

Avoid stacking appliances

A 3 kWp system scales to about 15.2 kWh for the day before household use. Run flexible loads sequentially during the strongest hours rather than assuming all forecast energy is simultaneous power.

Local questions

Solar forecast FAQ

How much could a 5 kWp solar system produce tomorrow in Catania?

Using the same south-facing, 35-degree and 14% loss assumptions, the 5 kWp estimate is 25.4 kWh for Tuesday, September 1, 2026, with a scaled likely range of 22.0 kWh–26.9 kWh. This is a linear reference-system estimate, not a site survey.

What does 1,564 kWh/kWp mean for Catania?

It means the PVGIS multi-year profile produces about 1,564 kWh in a typical year for each installed kWp under the reference assumptions. A 5 kWp system therefore scales to about 7,819 kWh in a typical year before site-specific adjustments.

Is the Catania forecast the same as the PVGIS annual estimate?

No. Tomorrow's forecast uses dated weather and an uncertainty band for one day. The PVGIS figure is a multi-year climate-based specific yield used for typical monthly and annual comparisons.

When should a battery, EV or heat pump use solar in Catania?

Start with 12:00-16:00, then check household base load, battery headroom, EV energy required and heat-pump safety or comfort constraints. The forecast estimates daily energy, not guaranteed instantaneous surplus.

Typical year

Solar production month by month in Catania

A standard 10 kWp system produces about 15,638 kWh in a typical year at this location. Monthly averages show seasonality; they are not a forecast for a specific year.

Values are kWh per month. Source: European Commission JRC PVGIS.

What makes Catania's solar profile different?The typical annual yield is about 1,564 kWh per installed kWp, ranking Catania #1 of 10 modelled locations in Italy. That is 9% above the median of the 10 Italy locations in this dataset. July is typically the strongest month and December the weakest; the stronger month produces about 1.6 times as much.

See the 12-month data
MonthMonthly outputDaily averageYear-to-year variation
MonthJanuaryMonthly output1,049 kWhDaily average33.8 kWh/dayYear-to-year variation±126 kWh
MonthFebruaryMonthly output1,098 kWhDaily average39.2 kWh/dayYear-to-year variation±145 kWh
MonthMarchMonthly output1,340 kWhDaily average43.2 kWh/dayYear-to-year variation±130 kWh
MonthAprilMonthly output1,398 kWhDaily average46.6 kWh/dayYear-to-year variation±108 kWh
MonthMayMonthly output1,503 kWhDaily average48.5 kWh/dayYear-to-year variation±106 kWh
MonthJuneMonthly output1,496 kWhDaily average49.9 kWh/dayYear-to-year variation±62 kWh
MonthJulyMonthly output1,617 kWhDaily average52.2 kWh/dayYear-to-year variation±34 kWh
MonthAugustMonthly output1,588 kWhDaily average51.2 kWh/dayYear-to-year variation±75 kWh
MonthSeptemberMonthly output1,346 kWhDaily average44.9 kWh/dayYear-to-year variation±77 kWh
MonthOctoberMonthly output1,195 kWhDaily average38.6 kWh/dayYear-to-year variation±126 kWh
MonthNovemberMonthly output1,024 kWhDaily average34.1 kWh/dayYear-to-year variation±104 kWh
MonthDecemberMonthly output983 kWhDaily average31.7 kWh/dayYear-to-year variation±94 kWh

Nearby solar forecasts

Compare Catania with nearby cities

Tomorrow, in one email

Get Catania's solar forecast by email

Tomorrow's expected production, likely range and strongest hours. One useful email each day.

Daily email only. Analytics is optional. Unsubscribe in one click.Privacy

Method and data

Every city uses a 10 kWp system facing south at 35 degrees with 14% system losses. Tomorrow's figure combines hourly weather with GridPassport's PV production and uncertainty model. The monthly profile uses the European Commission JRC PVGIS multi-year climate series. Roof direction, shade, snow, dirt, inverter clipping and local weather can change real output.

CSV and JSON snapshots are published under CC BY 4.0 with source attribution.