Netherlands · 10 kWp reference system

Assen solar forecast and PV yield

Forecast target: . Any “tomorrow” label on this page refers to this dated target.

Tomorrow's forecast
3.3 kWh
10 kWp reference system
Typical annual output
9,906 kWh
10 kWp reference system
Typical specific yield
991 kWh/kWp
Per year

Friday, October 23, 2026

About 3.3 kWh tomorrow

For a standard 10 kWp south-facing system in Assen, GridPassport estimates 3.3 kWh on Friday, October 23, 2026, with a likely range of 1.9-4.6 kWh. The strongest production window is expected at 12:00-16:00 local time.

Updated Oct 22, 2026, 04:01 AM GMT+2 · Automatically refreshed
Likely range
1.9-4.6 kWh
Strongest window
12:00-16:00
Confidence
medium
Forecast my solar output

Typical year

Solar production month by month in Assen

A standard 10 kWp system produces about 9,906 kWh in a typical year at this location. Monthly averages show seasonality; they are not a forecast for a specific year.

Values are kWh per month. Source: European Commission JRC PVGIS.

What makes Assen's solar profile different?The typical annual yield is about 991 kWh per installed kWp, ranking Assen #37 of 37 modelled locations in Netherlands. That is 4% below the median of the 37 Netherlands locations in this dataset. May is typically the strongest month and December the weakest; the stronger month produces about 5.0 times as much.

See the 12-month data
MonthMonthly outputDaily averageYear-to-year variation
MonthJanuaryMonthly output302 kWhDaily average9.7 kWh/dayYear-to-year variation±51 kWh
MonthFebruaryMonthly output474 kWhDaily average16.9 kWh/dayYear-to-year variation±113 kWh
MonthMarchMonthly output873 kWhDaily average28.2 kWh/dayYear-to-year variation±170 kWh
MonthAprilMonthly output1,195 kWhDaily average39.9 kWh/dayYear-to-year variation±155 kWh
MonthMayMonthly output1,262 kWhDaily average40.7 kWh/dayYear-to-year variation±144 kWh
MonthJuneMonthly output1,243 kWhDaily average41.4 kWh/dayYear-to-year variation±139 kWh
MonthJulyMonthly output1,226 kWhDaily average39.5 kWh/dayYear-to-year variation±159 kWh
MonthAugustMonthly output1,142 kWhDaily average36.8 kWh/dayYear-to-year variation±121 kWh
MonthSeptemberMonthly output934 kWhDaily average31.1 kWh/dayYear-to-year variation±99 kWh
MonthOctoberMonthly output639 kWhDaily average20.6 kWh/dayYear-to-year variation±119 kWh
MonthNovemberMonthly output361 kWhDaily average12.0 kWh/dayYear-to-year variation±61 kWh
MonthDecemberMonthly output255 kWhDaily average8.2 kWh/dayYear-to-year variation±67 kWh

How to read and use the data

Assen solar forecast: daily weather versus long-term PV yield

The daily and annual figures answer different questions. Use the dated forecast to plan tomorrow, and the PVGIS specific yield to compare locations or estimate a typical year.

Dated, weather-based

Tomorrow's forecast

Tomorrow's value is a weather-based estimate for Friday, October 23, 2026: 3.3 kWh from the 10 kWp reference system, with a likely range of 1.9 kWh–4.6 kWh. It changes with the next weather forecast.

Multi-year climate baseline

PVGIS specific yield

Assen's PVGIS specific yield is about 991 kWh/kWp per year. It is a multi-year climate benchmark, not a prediction for tomorrow or for this calendar year. In the PVGIS profile, May is typically the strongest month and December the weakest.

3, 5 and 10 kWp reference systems

Scale the same assumptions to your system size

SystemTomorrow estimate (likely range)PVGIS typical year
3 kWpTomorrow estimate (likely range)1.0 kWh0.6 kWh–1.4 kWhPVGIS typical year2,972 kWh/year
5 kWpTomorrow estimate (likely range)1.6 kWh0.9 kWh–2.3 kWhPVGIS typical year4,953 kWh/year
10 kWpTomorrow estimate (likely range)3.3 kWh1.9 kWh–4.6 kWhPVGIS typical year9,906 kWh/year

Linear reference scaling only: south-facing, 35° tilt and 14% system losses. It does not resize inverter clipping, shade or local roof constraints.

From forecast to a household plan

Battery, EV, heat pump and flexible loads

Treat the forecast as a gross solar-energy budget before household base load and conversion losses. The numbers support scheduling; they do not guarantee surplus.

Battery

Keep room for the solar window

Use 12:00-16:00 as the first candidate charging window. Battery state of charge, reserve settings and inverter limits still decide how much can be stored.

Heat pump

Shift only flexible thermal demand

If comfort controls allow it, place discretionary hot-water heating or pre-heating inside 12:00-16:00. Never override frost protection, hygiene cycles or manufacturer limits.

Large loads

Avoid stacking appliances

A 3 kWp system scales to about 1.0 kWh for the day before household use. Run flexible loads sequentially during the strongest hours rather than assuming all forecast energy is simultaneous power.

Local questions

Solar forecast FAQ

How much could a 5 kWp solar system produce tomorrow in Assen?

Using the same south-facing, 35-degree and 14% loss assumptions, the 5 kWp estimate is 1.6 kWh for Friday, October 23, 2026, with a scaled likely range of 0.9 kWh–2.3 kWh. This is a linear reference-system estimate, not a site survey.

What does 991 kWh/kWp mean for Assen?

It means the PVGIS multi-year profile produces about 991 kWh in a typical year for each installed kWp under the reference assumptions. A 5 kWp system therefore scales to about 4,953 kWh in a typical year before site-specific adjustments.

Is the Assen forecast the same as the PVGIS annual estimate?

No. Tomorrow's forecast uses dated weather and an uncertainty band for one day. The PVGIS figure is a multi-year climate-based specific yield used for typical monthly and annual comparisons.

When should a battery, EV or heat pump use solar in Assen?

Start with 12:00-16:00, then check household base load, battery headroom, EV energy required and heat-pump safety or comfort constraints. The forecast estimates daily energy, not guaranteed instantaneous surplus.

Checking your own installation? Learn how to compare a solar forecast with inverter production, or explore 5 kWp output in winter versus summer. Use the free PV forecast calculator for your exact location and roof settings.

Nearby solar forecasts

Compare Assen with nearby cities

Tomorrow, in one email

Get Assen's solar forecast by email

Tomorrow's expected production, likely range and strongest hours. One useful email each day.

Daily email only. Analytics is optional. Unsubscribe in one click.Privacy

Method and data

Every city uses a 10 kWp system facing south at 35 degrees with 14% system losses. Tomorrow's figure combines hourly weather with GridPassport's PV production and uncertainty model. The monthly profile uses the European Commission JRC PVGIS multi-year climate series. Roof direction, shade, snow, dirt, inverter clipping and local weather can change real output.

CSV and JSON snapshots are published under CC BY 4.0 with source attribution.