Netherlands · 10 kWp reference system

Deventer solar forecast and PV yield

Forecast target: . Any “tomorrow” label on this page refers to this dated target.

Tomorrow's forecast
4.7 kWh
10 kWp reference system
Typical annual output
10,185 kWh
10 kWp reference system
Typical specific yield
1,018 kWh/kWp
Per year

Friday, October 23, 2026

About 4.7 kWh tomorrow

For a standard 10 kWp south-facing system in Deventer, GridPassport estimates 4.7 kWh on Friday, October 23, 2026, with a likely range of 2.7-6.7 kWh. The strongest production window is expected at 13:00-17:00 local time.

Updated Oct 22, 2026, 04:01 AM GMT+2 · Automatically refreshed
Likely range
2.7-6.7 kWh
Strongest window
13:00-17:00
Confidence
medium
Forecast my solar output

Typical year

Solar production month by month in Deventer

A standard 10 kWp system produces about 10,185 kWh in a typical year at this location. Monthly averages show seasonality; they are not a forecast for a specific year.

Values are kWh per month. Source: European Commission JRC PVGIS.

What makes Deventer's solar profile different?The typical annual yield is about 1,018 kWh per installed kWp, ranking Deventer #28 of 37 modelled locations in Netherlands. That is 1% below the median of the 37 Netherlands locations in this dataset. May is typically the strongest month and December the weakest; the stronger month produces about 4.6 times as much.

See the 12-month data
MonthMonthly outputDaily averageYear-to-year variation
MonthJanuaryMonthly output330 kWhDaily average10.7 kWh/dayYear-to-year variation±54 kWh
MonthFebruaryMonthly output506 kWhDaily average18.1 kWh/dayYear-to-year variation±128 kWh
MonthMarchMonthly output897 kWhDaily average28.9 kWh/dayYear-to-year variation±169 kWh
MonthAprilMonthly output1,199 kWhDaily average40.0 kWh/dayYear-to-year variation±153 kWh
MonthMayMonthly output1,275 kWhDaily average41.1 kWh/dayYear-to-year variation±157 kWh
MonthJuneMonthly output1,272 kWhDaily average42.4 kWh/dayYear-to-year variation±142 kWh
MonthJulyMonthly output1,246 kWhDaily average40.2 kWh/dayYear-to-year variation±163 kWh
MonthAugustMonthly output1,154 kWhDaily average37.2 kWh/dayYear-to-year variation±117 kWh
MonthSeptemberMonthly output959 kWhDaily average32.0 kWh/dayYear-to-year variation±101 kWh
MonthOctoberMonthly output678 kWhDaily average21.9 kWh/dayYear-to-year variation±112 kWh
MonthNovemberMonthly output390 kWhDaily average13.0 kWh/dayYear-to-year variation±69 kWh
MonthDecemberMonthly output279 kWhDaily average9.0 kWh/dayYear-to-year variation±72 kWh

How to read and use the data

Deventer solar forecast: daily weather versus long-term PV yield

The daily and annual figures answer different questions. Use the dated forecast to plan tomorrow, and the PVGIS specific yield to compare locations or estimate a typical year.

Dated, weather-based

Tomorrow's forecast

Tomorrow's value is a weather-based estimate for Friday, October 23, 2026: 4.7 kWh from the 10 kWp reference system, with a likely range of 2.7 kWh–6.7 kWh. It changes with the next weather forecast.

Multi-year climate baseline

PVGIS specific yield

Deventer's PVGIS specific yield is about 1,018 kWh/kWp per year. It is a multi-year climate benchmark, not a prediction for tomorrow or for this calendar year. In the PVGIS profile, May is typically the strongest month and December the weakest.

3, 5 and 10 kWp reference systems

Scale the same assumptions to your system size

SystemTomorrow estimate (likely range)PVGIS typical year
3 kWpTomorrow estimate (likely range)1.4 kWh0.8 kWh–2.0 kWhPVGIS typical year3,055 kWh/year
5 kWpTomorrow estimate (likely range)2.4 kWh1.4 kWh–3.4 kWhPVGIS typical year5,092 kWh/year
10 kWpTomorrow estimate (likely range)4.7 kWh2.7 kWh–6.7 kWhPVGIS typical year10,185 kWh/year

Linear reference scaling only: south-facing, 35° tilt and 14% system losses. It does not resize inverter clipping, shade or local roof constraints.

From forecast to a household plan

Battery, EV, heat pump and flexible loads

Treat the forecast as a gross solar-energy budget before household base load and conversion losses. The numbers support scheduling; they do not guarantee surplus.

Battery

Keep room for the solar window

Use 13:00-17:00 as the first candidate charging window. Battery state of charge, reserve settings and inverter limits still decide how much can be stored.

Heat pump

Shift only flexible thermal demand

If comfort controls allow it, place discretionary hot-water heating or pre-heating inside 13:00-17:00. Never override frost protection, hygiene cycles or manufacturer limits.

Large loads

Avoid stacking appliances

A 3 kWp system scales to about 1.4 kWh for the day before household use. Run flexible loads sequentially during the strongest hours rather than assuming all forecast energy is simultaneous power.

Local questions

Solar forecast FAQ

How much could a 5 kWp solar system produce tomorrow in Deventer?

Using the same south-facing, 35-degree and 14% loss assumptions, the 5 kWp estimate is 2.4 kWh for Friday, October 23, 2026, with a scaled likely range of 1.4 kWh–3.4 kWh. This is a linear reference-system estimate, not a site survey.

What does 1,018 kWh/kWp mean for Deventer?

It means the PVGIS multi-year profile produces about 1,018 kWh in a typical year for each installed kWp under the reference assumptions. A 5 kWp system therefore scales to about 5,092 kWh in a typical year before site-specific adjustments.

Is the Deventer forecast the same as the PVGIS annual estimate?

No. Tomorrow's forecast uses dated weather and an uncertainty band for one day. The PVGIS figure is a multi-year climate-based specific yield used for typical monthly and annual comparisons.

When should a battery, EV or heat pump use solar in Deventer?

Start with 13:00-17:00, then check household base load, battery headroom, EV energy required and heat-pump safety or comfort constraints. The forecast estimates daily energy, not guaranteed instantaneous surplus.

Checking your own installation? Learn how to compare a solar forecast with inverter production, or explore 5 kWp output in winter versus summer. Use the free PV forecast calculator for your exact location and roof settings.

Nearby solar forecasts

Compare Deventer with nearby cities

Tomorrow, in one email

Get Deventer's solar forecast by email

Tomorrow's expected production, likely range and strongest hours. One useful email each day.

Daily email only. Analytics is optional. Unsubscribe in one click.Privacy

Method and data

Every city uses a 10 kWp system facing south at 35 degrees with 14% system losses. Tomorrow's figure combines hourly weather with GridPassport's PV production and uncertainty model. The monthly profile uses the European Commission JRC PVGIS multi-year climate series. Roof direction, shade, snow, dirt, inverter clipping and local weather can change real output.

CSV and JSON snapshots are published under CC BY 4.0 with source attribution.