Göteborg Sweden July 2016

Sweden · 10 kWp reference system

Gothenburg solar forecast and PV yield

Photo: Bengt Nyman from Vaxholm, Sweden,CC BY 2.0. Cropped, resized and converted to WebP by GridPassport.

Forecast target: . Any “tomorrow” label on this page refers to this dated target.

Tomorrow's forecast
27.7 kWh
10 kWp reference system
Typical annual output
9,511 kWh
10 kWp reference system
Typical specific yield
951 kWh/kWp
Per year

Tuesday, September 1, 2026

About 27.7 kWh tomorrow

For a standard 10 kWp south-facing system in Gothenburg, GridPassport estimates 27.7 kWh on Tuesday, September 1, 2026, with a likely range of 18.0-34.8 kWh. The strongest production window is expected at 14:00-18:00 local time.

Updated Aug 31, 2026, 01:01 AM GMT+2 · fresh snapshot
Likely range
18.0-34.8 kWh
Strongest window
14:00-18:00
Confidence
medium
Forecast my solar output

How to read and use the data

Gothenburg solar forecast: daily weather versus long-term PV yield

The daily and annual figures answer different questions. Use the dated forecast to plan tomorrow, and the PVGIS specific yield to compare locations or estimate a typical year.

Dated, weather-based

Tomorrow's forecast

Tomorrow's value is a weather-based estimate for Tuesday, September 1, 2026: 27.7 kWh from the 10 kWp reference system, with a likely range of 18.0 kWh–34.8 kWh. It changes with the next weather forecast.

Multi-year climate baseline

PVGIS specific yield

Gothenburg's PVGIS specific yield is about 951 kWh/kWp per year. It is a multi-year climate benchmark, not a prediction for tomorrow or for this calendar year. In the PVGIS profile, May is typically the strongest month and December the weakest.

3, 5 and 10 kWp reference systems

Scale the same assumptions to your system size

SystemTomorrow estimate (likely range)PVGIS typical year
3 kWpTomorrow estimate (likely range)8.3 kWh5.4 kWh–10.4 kWhPVGIS typical year2,853 kWh/year
5 kWpTomorrow estimate (likely range)13.8 kWh9.0 kWh–17.4 kWhPVGIS typical year4,755 kWh/year
10 kWpTomorrow estimate (likely range)27.7 kWh18.0 kWh–34.8 kWhPVGIS typical year9,511 kWh/year

Linear reference scaling only: south-facing, 35° tilt and 14% system losses. It does not resize inverter clipping, shade or local roof constraints.

From forecast to a household plan

Battery, EV, heat pump and flexible loads

Treat the forecast as a gross solar-energy budget before household base load and conversion losses. The numbers support scheduling; they do not guarantee surplus.

Battery

Keep room for the solar window

Use 14:00-18:00 as the first candidate charging window. Battery state of charge, reserve settings and inverter limits still decide how much can be stored.

Heat pump

Shift only flexible thermal demand

If comfort controls allow it, place discretionary hot-water heating or pre-heating inside 14:00-18:00. Never override frost protection, hygiene cycles or manufacturer limits.

Large loads

Avoid stacking appliances

A 3 kWp system scales to about 8.3 kWh for the day before household use. Run flexible loads sequentially during the strongest hours rather than assuming all forecast energy is simultaneous power.

Local questions

Solar forecast FAQ

How much could a 5 kWp solar system produce tomorrow in Gothenburg?

Using the same south-facing, 35-degree and 14% loss assumptions, the 5 kWp estimate is 13.8 kWh for Tuesday, September 1, 2026, with a scaled likely range of 9.0 kWh–17.4 kWh. This is a linear reference-system estimate, not a site survey.

What does 951 kWh/kWp mean for Gothenburg?

It means the PVGIS multi-year profile produces about 951 kWh in a typical year for each installed kWp under the reference assumptions. A 5 kWp system therefore scales to about 4,755 kWh in a typical year before site-specific adjustments.

Is the Gothenburg forecast the same as the PVGIS annual estimate?

No. Tomorrow's forecast uses dated weather and an uncertainty band for one day. The PVGIS figure is a multi-year climate-based specific yield used for typical monthly and annual comparisons.

When should a battery, EV or heat pump use solar in Gothenburg?

Start with 14:00-18:00, then check household base load, battery headroom, EV energy required and heat-pump safety or comfort constraints. The forecast estimates daily energy, not guaranteed instantaneous surplus.

Typical year

Solar production month by month in Gothenburg

A standard 10 kWp system produces about 9,511 kWh in a typical year at this location. Monthly averages show seasonality; they are not a forecast for a specific year.

Values are kWh per month. Source: European Commission JRC PVGIS.

What makes Gothenburg's solar profile different?The typical annual yield is about 951 kWh per installed kWp, ranking Gothenburg #5 of 7 modelled locations in Sweden. That is close to the median of the 7 Sweden locations in this dataset. May is typically the strongest month and December the weakest; the stronger month produces about 9.7 times as much.

See the 12-month data
MonthMonthly outputDaily averageYear-to-year variation
MonthJanuaryMonthly output212 kWhDaily average6.8 kWh/dayYear-to-year variation±46 kWh
MonthFebruaryMonthly output406 kWhDaily average14.5 kWh/dayYear-to-year variation±79 kWh
MonthMarchMonthly output891 kWhDaily average28.7 kWh/dayYear-to-year variation±173 kWh
MonthAprilMonthly output1,224 kWhDaily average40.8 kWh/dayYear-to-year variation±184 kWh
MonthMayMonthly output1,354 kWhDaily average43.7 kWh/dayYear-to-year variation±188 kWh
MonthJuneMonthly output1,349 kWhDaily average45.0 kWh/dayYear-to-year variation±112 kWh
MonthJulyMonthly output1,277 kWhDaily average41.2 kWh/dayYear-to-year variation±174 kWh
MonthAugustMonthly output1,073 kWhDaily average34.6 kWh/dayYear-to-year variation±123 kWh
MonthSeptemberMonthly output827 kWhDaily average27.6 kWh/dayYear-to-year variation±127 kWh
MonthOctoberMonthly output523 kWhDaily average16.9 kWh/dayYear-to-year variation±101 kWh
MonthNovemberMonthly output236 kWhDaily average7.9 kWh/dayYear-to-year variation±57 kWh
MonthDecemberMonthly output139 kWhDaily average4.5 kWh/dayYear-to-year variation±43 kWh

Nearby solar forecasts

Compare Gothenburg with nearby cities

Tomorrow, in one email

Get Gothenburg's solar forecast by email

Tomorrow's expected production, likely range and strongest hours. One useful email each day.

Daily email only. Analytics is optional. Unsubscribe in one click.Privacy

Method and data

Every city uses a 10 kWp system facing south at 35 degrees with 14% system losses. Tomorrow's figure combines hourly weather with GridPassport's PV production and uncertainty model. The monthly profile uses the European Commission JRC PVGIS multi-year climate series. Roof direction, shade, snow, dirt, inverter clipping and local weather can change real output.

CSV and JSON snapshots are published under CC BY 4.0 with source attribution.