(30) VIEW ON PEDESTRIAN BRIDGE OVER KHARKIV RIVER IN CITY OF KHARKIV STATE OF UKRAINE PHOTOGRAPH BY VIKTOR O LEDENYOV 20160616

Ukraine · 10 kWp reference system

Kharkiv solar forecast and PV yield

Photo: Viktor O. Ledenyov,CC BY-SA 4.0. Cropped, resized and converted to WebP by GridPassport.

Forecast target: . Any “tomorrow” label on this page refers to this dated target.

Tomorrow's forecast
50.9 kWh
10 kWp reference system
Typical annual output
11,324 kWh
10 kWp reference system
Typical specific yield
1,132 kWh/kWp
Per year

Tuesday, September 1, 2026

About 50.9 kWh tomorrow

For a standard 10 kWp south-facing system in Kharkiv, GridPassport estimates 50.9 kWh on Tuesday, September 1, 2026, with a likely range of 38.7-55.7 kWh. The strongest production window is expected at 11:00-15:00 local time.

Updated Aug 31, 2026, 02:01 AM GMT+3 · fresh snapshot
Likely range
38.7-55.7 kWh
Strongest window
11:00-15:00
Confidence
medium
Forecast my solar output

How to read and use the data

Kharkiv solar forecast: daily weather versus long-term PV yield

The daily and annual figures answer different questions. Use the dated forecast to plan tomorrow, and the PVGIS specific yield to compare locations or estimate a typical year.

Dated, weather-based

Tomorrow's forecast

Tomorrow's value is a weather-based estimate for Tuesday, September 1, 2026: 50.9 kWh from the 10 kWp reference system, with a likely range of 38.7 kWh–55.7 kWh. It changes with the next weather forecast.

Multi-year climate baseline

PVGIS specific yield

Kharkiv's PVGIS specific yield is about 1,132 kWh/kWp per year. It is a multi-year climate benchmark, not a prediction for tomorrow or for this calendar year. In the PVGIS profile, July is typically the strongest month and December the weakest.

3, 5 and 10 kWp reference systems

Scale the same assumptions to your system size

SystemTomorrow estimate (likely range)PVGIS typical year
3 kWpTomorrow estimate (likely range)15.3 kWh11.6 kWh–16.7 kWhPVGIS typical year3,397 kWh/year
5 kWpTomorrow estimate (likely range)25.4 kWh19.4 kWh–27.9 kWhPVGIS typical year5,662 kWh/year
10 kWpTomorrow estimate (likely range)50.9 kWh38.7 kWh–55.7 kWhPVGIS typical year11,324 kWh/year

Linear reference scaling only: south-facing, 35° tilt and 14% system losses. It does not resize inverter clipping, shade or local roof constraints.

From forecast to a household plan

Battery, EV, heat pump and flexible loads

Treat the forecast as a gross solar-energy budget before household base load and conversion losses. The numbers support scheduling; they do not guarantee surplus.

Battery

Keep room for the solar window

Use 11:00-15:00 as the first candidate charging window. Battery state of charge, reserve settings and inverter limits still decide how much can be stored.

Heat pump

Shift only flexible thermal demand

If comfort controls allow it, place discretionary hot-water heating or pre-heating inside 11:00-15:00. Never override frost protection, hygiene cycles or manufacturer limits.

Large loads

Avoid stacking appliances

A 3 kWp system scales to about 15.3 kWh for the day before household use. Run flexible loads sequentially during the strongest hours rather than assuming all forecast energy is simultaneous power.

Local questions

Solar forecast FAQ

How much could a 5 kWp solar system produce tomorrow in Kharkiv?

Using the same south-facing, 35-degree and 14% loss assumptions, the 5 kWp estimate is 25.4 kWh for Tuesday, September 1, 2026, with a scaled likely range of 19.4 kWh–27.9 kWh. This is a linear reference-system estimate, not a site survey.

What does 1,132 kWh/kWp mean for Kharkiv?

It means the PVGIS multi-year profile produces about 1,132 kWh in a typical year for each installed kWp under the reference assumptions. A 5 kWp system therefore scales to about 5,662 kWh in a typical year before site-specific adjustments.

Is the Kharkiv forecast the same as the PVGIS annual estimate?

No. Tomorrow's forecast uses dated weather and an uncertainty band for one day. The PVGIS figure is a multi-year climate-based specific yield used for typical monthly and annual comparisons.

When should a battery, EV or heat pump use solar in Kharkiv?

Start with 11:00-15:00, then check household base load, battery headroom, EV energy required and heat-pump safety or comfort constraints. The forecast estimates daily energy, not guaranteed instantaneous surplus.

Typical year

Solar production month by month in Kharkiv

A standard 10 kWp system produces about 11,324 kWh in a typical year at this location. Monthly averages show seasonality; they are not a forecast for a specific year.

Values are kWh per month. Source: European Commission JRC PVGIS.

What makes Kharkiv's solar profile different?The typical annual yield is about 1,132 kWh per installed kWp, ranking Kharkiv #5 of 8 modelled locations in Ukraine. That is close to the median of the 8 Ukraine locations in this dataset. July is typically the strongest month and December the weakest; the stronger month produces about 5.9 times as much.

See the 12-month data
MonthMonthly outputDaily averageYear-to-year variation
MonthJanuaryMonthly output404 kWhDaily average13.0 kWh/dayYear-to-year variation±127 kWh
MonthFebruaryMonthly output577 kWhDaily average20.6 kWh/dayYear-to-year variation±160 kWh
MonthMarchMonthly output920 kWhDaily average29.7 kWh/dayYear-to-year variation±165 kWh
MonthAprilMonthly output1,152 kWhDaily average38.4 kWh/dayYear-to-year variation±155 kWh
MonthMayMonthly output1,373 kWhDaily average44.3 kWh/dayYear-to-year variation±118 kWh
MonthJuneMonthly output1,423 kWhDaily average47.4 kWh/dayYear-to-year variation±90 kWh
MonthJulyMonthly output1,457 kWhDaily average47.0 kWh/dayYear-to-year variation±70 kWh
MonthAugustMonthly output1,436 kWhDaily average46.3 kWh/dayYear-to-year variation±113 kWh
MonthSeptemberMonthly output1,152 kWhDaily average38.4 kWh/dayYear-to-year variation±201 kWh
MonthOctoberMonthly output796 kWhDaily average25.7 kWh/dayYear-to-year variation±192 kWh
MonthNovemberMonthly output385 kWhDaily average12.8 kWh/dayYear-to-year variation±101 kWh
MonthDecemberMonthly output248 kWhDaily average8.0 kWh/dayYear-to-year variation±45 kWh

Nearby solar forecasts

Compare Kharkiv with nearby cities

Tomorrow, in one email

Get Kharkiv's solar forecast by email

Tomorrow's expected production, likely range and strongest hours. One useful email each day.

Daily email only. Analytics is optional. Unsubscribe in one click.Privacy

Method and data

Every city uses a 10 kWp system facing south at 35 degrees with 14% system losses. Tomorrow's figure combines hourly weather with GridPassport's PV production and uncertainty model. The monthly profile uses the European Commission JRC PVGIS multi-year climate series. Roof direction, shade, snow, dirt, inverter clipping and local weather can change real output.

CSV and JSON snapshots are published under CC BY 4.0 with source attribution.