Bergen panorama at night

Norway · 10 kWp reference system

Bergen solar forecast and PV yield

Photo: TomasEE,CC BY 3.0. Cropped, resized and converted to WebP by GridPassport.

Forecast target: . Any “tomorrow” label on this page refers to this dated target.

Tomorrow's forecast
5.7 kWh
10 kWp reference system
Typical annual output
7,226 kWh
10 kWp reference system
Typical specific yield
723 kWh/kWp
Per year

Tuesday, September 1, 2026

About 5.7 kWh tomorrow

For a standard 10 kWp south-facing system in Bergen, GridPassport estimates 5.7 kWh on Tuesday, September 1, 2026, with a likely range of 3.4-7.9 kWh. The strongest production window is expected at 16:00-20:00 local time.

Updated Aug 31, 2026, 01:01 AM GMT+2 · fresh snapshot
Likely range
3.4-7.9 kWh
Strongest window
16:00-20:00
Confidence
medium
Forecast my solar output

How to read and use the data

Bergen solar forecast: daily weather versus long-term PV yield

The daily and annual figures answer different questions. Use the dated forecast to plan tomorrow, and the PVGIS specific yield to compare locations or estimate a typical year.

Dated, weather-based

Tomorrow's forecast

Tomorrow's value is a weather-based estimate for Tuesday, September 1, 2026: 5.7 kWh from the 10 kWp reference system, with a likely range of 3.4 kWh–7.9 kWh. It changes with the next weather forecast.

Multi-year climate baseline

PVGIS specific yield

Bergen's PVGIS specific yield is about 723 kWh/kWp per year. It is a multi-year climate benchmark, not a prediction for tomorrow or for this calendar year. In the PVGIS profile, June is typically the strongest month and December the weakest.

3, 5 and 10 kWp reference systems

Scale the same assumptions to your system size

SystemTomorrow estimate (likely range)PVGIS typical year
3 kWpTomorrow estimate (likely range)1.7 kWh1.0 kWh–2.4 kWhPVGIS typical year2,168 kWh/year
5 kWpTomorrow estimate (likely range)2.9 kWh1.7 kWh–4.0 kWhPVGIS typical year3,613 kWh/year
10 kWpTomorrow estimate (likely range)5.7 kWh3.4 kWh–7.9 kWhPVGIS typical year7,226 kWh/year

Linear reference scaling only: south-facing, 35° tilt and 14% system losses. It does not resize inverter clipping, shade or local roof constraints.

From forecast to a household plan

Battery, EV, heat pump and flexible loads

Treat the forecast as a gross solar-energy budget before household base load and conversion losses. The numbers support scheduling; they do not guarantee surplus.

Battery

Keep room for the solar window

Use 16:00-20:00 as the first candidate charging window. Battery state of charge, reserve settings and inverter limits still decide how much can be stored.

Heat pump

Shift only flexible thermal demand

If comfort controls allow it, place discretionary hot-water heating or pre-heating inside 16:00-20:00. Never override frost protection, hygiene cycles or manufacturer limits.

Large loads

Avoid stacking appliances

A 3 kWp system scales to about 1.7 kWh for the day before household use. Run flexible loads sequentially during the strongest hours rather than assuming all forecast energy is simultaneous power.

Local questions

Solar forecast FAQ

How much could a 5 kWp solar system produce tomorrow in Bergen?

Using the same south-facing, 35-degree and 14% loss assumptions, the 5 kWp estimate is 2.9 kWh for Tuesday, September 1, 2026, with a scaled likely range of 1.7 kWh–4.0 kWh. This is a linear reference-system estimate, not a site survey.

What does 723 kWh/kWp mean for Bergen?

It means the PVGIS multi-year profile produces about 723 kWh in a typical year for each installed kWp under the reference assumptions. A 5 kWp system therefore scales to about 3,613 kWh in a typical year before site-specific adjustments.

Is the Bergen forecast the same as the PVGIS annual estimate?

No. Tomorrow's forecast uses dated weather and an uncertainty band for one day. The PVGIS figure is a multi-year climate-based specific yield used for typical monthly and annual comparisons.

When should a battery, EV or heat pump use solar in Bergen?

Start with 16:00-20:00, then check household base load, battery headroom, EV energy required and heat-pump safety or comfort constraints. The forecast estimates daily energy, not guaranteed instantaneous surplus.

Typical year

Solar production month by month in Bergen

A standard 10 kWp system produces about 7,226 kWh in a typical year at this location. Monthly averages show seasonality; they are not a forecast for a specific year.

Values are kWh per month. Source: European Commission JRC PVGIS.

What makes Bergen's solar profile different?The typical annual yield is about 723 kWh per installed kWp, ranking Bergen #6 of 7 modelled locations in Norway. That is 12% below the median of the 7 Norway locations in this dataset. June is typically the strongest month and December the weakest; the stronger month produces about 102.9 times as much.

See the 12-month data
MonthMonthly outputDaily averageYear-to-year variation
MonthJanuaryMonthly output29 kWhDaily average0.9 kWh/dayYear-to-year variation±9 kWh
MonthFebruaryMonthly output276 kWhDaily average9.9 kWh/dayYear-to-year variation±75 kWh
MonthMarchMonthly output669 kWhDaily average21.6 kWh/dayYear-to-year variation±205 kWh
MonthAprilMonthly output957 kWhDaily average31.9 kWh/dayYear-to-year variation±147 kWh
MonthMayMonthly output1,159 kWhDaily average37.4 kWh/dayYear-to-year variation±176 kWh
MonthJuneMonthly output1,163 kWhDaily average38.8 kWh/dayYear-to-year variation±214 kWh
MonthJulyMonthly output1,028 kWhDaily average33.1 kWh/dayYear-to-year variation±170 kWh
MonthAugustMonthly output875 kWhDaily average28.2 kWh/dayYear-to-year variation±149 kWh
MonthSeptemberMonthly output591 kWhDaily average19.7 kWh/dayYear-to-year variation±148 kWh
MonthOctoberMonthly output383 kWhDaily average12.3 kWh/dayYear-to-year variation±106 kWh
MonthNovemberMonthly output84 kWhDaily average2.8 kWh/dayYear-to-year variation±22 kWh
MonthDecemberMonthly output11 kWhDaily average0.4 kWh/dayYear-to-year variation±3 kWh

Nearby solar forecasts

Compare Bergen with nearby cities

Tomorrow, in one email

Get Bergen's solar forecast by email

Tomorrow's expected production, likely range and strongest hours. One useful email each day.

Daily email only. Analytics is optional. Unsubscribe in one click.Privacy

Method and data

Every city uses a 10 kWp system facing south at 35 degrees with 14% system losses. Tomorrow's figure combines hourly weather with GridPassport's PV production and uncertainty model. The monthly profile uses the European Commission JRC PVGIS multi-year climate series. Roof direction, shade, snow, dirt, inverter clipping and local weather can change real output.

CSV and JSON snapshots are published under CC BY 4.0 with source attribution.